Abstract
Aim: To assess the safety and clinical and radiological outcome of the TruFit CB porous, resorbable scaffold for symptomatic osteochondral and chondral articular defects in the knee.
Methods: 11 active sporting patients underwent cartilage repair using TruFit CB plugs (Smith & Nephew) for symptomatic defects on the medial or lateral femoral condyle. All had failed previous treatment (debridement/microfracture) and had persistent symptoms. Postoperatively patients were touch weight bearing for 2 weeks and partial until 4 weeks. Data was collected prospectively. The mean age was 34 (range 19 – 50) and 5 were male. Four lateral femoral condyle defects were treated, all associated with lateral meniscal tears. Four medial defects were associated with ACL injury (1), PCL injury (1) or isolated chondral injury (2). Single plugs were required in 5 (9mm in 3 and 7mm plugs in 2), 2 patients required 2 plugs (9mm and 7mm), and 2 required 3 (2×9mm + 1×7mm).
Results: All 11 patients were improved at a mean follow up of 14.5 months (3–21 months) with 4 currently back to full pre-injury level of sport. Subjective IKDC scores improved from 45 pre-op to 79 post-op (p< 0.05), Lysholm from 47 to 71 (p< 0.05), and latest Tegner activity score at 5. MRI evaluation including T2 mapping demonstrates reformation of the subchondral lamina and resorption of the graft. 2nd look arthroscopy was undertaken in 2 showing a well healed and well integrated surface.
Conclusion: These preliminary results indicate that TruFit CB plugs offer a potential solution for small focal chondral defects, offering an alternative to microfracture or osteochondral grafting with advantages of low morbidity and rapid recovery without the need for prolonged non-weight bearing.
Correspondence should be addressed to Mr T Wilton, c/o BOA, BASK at the Royal College of Surgeons, 35–43 Lincoln’s Inn Fields, London WC2A 3PE, England.