THREE PIN VERSUS TWO PIN NAVIGATED KNEE REPLACEMENT



Abstract

The use of navigation systems to aid in the performance of total knee replacement has become an accepted method of treatment. Previous studies have shown that by using computer aided navigation the components can be implanted with more reproducible accuracy.

We present the results of a prospective randomised trial, with ethical committee approval that was performed to compare the use of a new, two-pin system with the original three-pin system to fix the tracker to bone. There were 37 patients in the two-pin group and 31 patients in the three-pin group. Pre-operative demographic data was similar. Patients were assessed pre and post operatively clinically using the Knee Society Score, WOMAC and SF36. Radiographic assessment was performed using “The Perth CT Protocol.”

At one year there was no significant difference clinically between either group. Radiographic assessment showed no significant difference in the results of all the prosthesis variables as measured by the Perth CT Protocol, except in the femoral prosthesis absolute varus/ valgus position, with the two-pin group being more accurate. The upgraded tracker fixing system in the computer navigation system allows as accurate implantation as the earlier system with less patient morbidity.

Address for Correspondence: Mr K Deep, General Secretary CAOS UK, 82 Windmill Road, Gillingham, Kent ME7 5NX UK. E Mail: caosuk@gmail.com