Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

INTRAOPERATIVE EFFECT OF METAL-ON-METAL HIP RESURFACING ARTHROPLASTY ON FEMORAL HEAD PERFUSION



Abstract

Introduction: The incidence of femoral neck fracture is approximately 2% after resurfacing hip replacement. Avascular necrosis is thought to be a contributory factor. The aim of this study was to investigate oxygen concentration in the femoral head during metal-on-metal hip resurfacing (MMHR).

Materials and Methods: In ten patients, following division of the fascia lata, a calibrated gas-measuring electrode was inserted into the supero-lateral quadrant of the femoral head via the femoral neck. Xsrays confirmed placement of the electrode 2-3 cms below the femoral head surface. Baseline oxygen concentration levels were recorded immediately upon electrode insertion and used as a reference for all intra-operative measures. Oxygen levels were monitored continuously throughout the operation.

Results: Oxygen concentration was reduced during the surgical approach and average oxygen concentration following dislocation and circumferential capsulotomy dropped significantly (p< 0.005) to 38% of baseline (SD=26%). Insertion of implants resulted in a further significant drop in oxygen concentration (p< 0.04) to 21% of baseline (SD=28%). Oxygen concentration rose slightly, but not significantly after relocation of the resurfaced joint and reconstruction of posterior soft tissues, reaching 22% of initial baseline oxygen levels. Considerable variation between subjects was observed.

Discussion: Intra-operative measurement of oxygen concentration in blood perfusing the femoral head is possible. During MMHR there is a dramatic decrease in femoral head oxygenation during surgical approach and implant fixation. This may increase the risk of avascular necrosis and subsequent femoral neck fracture. Future experiments will determine if a different surgical approach can protect the blood supply to the femoral head and neck. Measurements of femoral head oxygenation during metal-on-metal hip resurfacing demonstrated a significant concentration decrease during surgical approach and implant fixation.

Editorial Secretaries: Lynne C. Jones, Ph.D.* and Michael A. Mont, M.D. Address for Correspondence: *Lynne C. Jones, Ph.D., Suite 201 GSH POB, 5601 Loch Raven Blvd., Baltimore, MD 21239, USA. Email: ljones3@jhmi.edu