Abstract
This study examined the reliability of pre-operative templating of the femur in total hip replacement (THR), and the accuracy of the templates provided by leading arthroplasty manufacturers. Templates are provided by arthroplasty manufacturers to be used with pre-operative radiographs as an aid to selecting the appropriate size of prosthesis that will allow an optimal cement mantle in THR. These templates vary in magnification from 10-20% (Mode 15%).
A retrospective review of the pre- and post-operative AP pelvis radiographs of 50 randomly selected patients who underwent THR in 1998 was performed. The radiographs were taken using the uniform standard technique. The magnification of the post-op radiograph was calculated by measuring the femoral head size. This was compared to the magnification of the pre-op radiographs using the ratio of the inter-teardrop distance. The post-operative radiographs were templated using a 15% template and compared to the size of prosthesis inserted.
The mean radiograph magnification was 22.5% (range 10.7 to 32.6%), with the majority (74%) between 20–25%. The 15% template oversized the prosthesis in 68% of cases. A 10% template would have been inaccurate in 96% of our sample group.
In a standard AP pelvis radiograph, the only variable that affects magnification is the extent to which the patient’s soft tissues raise the bony structures away from the plate. This variation in magnification renders preoperative templating of the femur in THR unreliable. Accuracy could be improved by using templates with a magnification of 22.5%.
The abstracts were prepared by David P. Davlin. Correspondence should be addressed to him at the Orthopedic Clinic Bulovka, Budínova 2, 18081 Prague 8, Czech Republic.