header advert
Results 1 - 6 of 6
Results per page:
Bone & Joint Open
Vol. 3, Issue 8 | Pages 628 - 640
1 Aug 2022
Phoon KM Afzal I Sochart DH Asopa V Gikas P Kader D

Aims

In the UK, the NHS generates an estimated 25 megatonnes of carbon dioxide equivalents (4% to 5% of the nation’s total carbon emissions) and produces over 500,000 tonnes of waste annually. There is limited evidence demonstrating the principles of sustainability and its benefits within orthopaedic surgery. The primary aim of this study was to analyze the environmental impact of orthopaedic surgery and the environmentally sustainable initiatives undertaken to address this. The secondary aim of this study was to describe the barriers to making sustainable changes within orthopaedic surgery.

Methods

A literature search was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines through EMBASE, Medline, and PubMed libraries using two domains of terms: “orthopaedic surgery” and “environmental sustainability”.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 18 - 18
1 Dec 2014
Olivier A Briggs T Khan S Faimali M Johnston L Gikas P Skinner J Pollock R Aston W
Full Access

Introduction:

Pigmented Villonodular Synovitis (PVNS) is a rare inflammatory disorder of the synovium, bursa and tendon sheath. The objective of this study was to evaluate the long-term outcomes and morbidity associated with operative management of PVNS of the hand.

Methods:

Histological databases were retrospectively interrogated. All patients between 2003–2008 with confirmed PVNS of the hand were included in the study.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 29 - 29
1 Dec 2014
Olivier A Briggs T Khan S Johnston L Faimali M Gikas P Jagiello J Skinner J Aston W Pollock R
Full Access

Introduction:

Endoprosthetic replacement of the proximal femur is common in the management of bone tumours and failed revision arthroplasty. This study seeks to compare those patients undergoing acetabular resurfacing at the time of femoral replacement with those patients where the native acetabulum was preserved.

Methods:

All proximal femoral replacements from 2004 to 2009 with a five year follow up were included. Case files were interrogated to identify those that had either revision surgery or dislocation of the hip.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 58 - 58
1 Dec 2014
Olivier A Briggs T Khan S Faimali M Johnston L Gikas P Skinner J Pollock R Aston W
Full Access

Introduction:

Distal femoral replacement is recognised as the optimum treatment for malignant distal femoral tumours. Aseptic loosening is known to be a major cause for failure in these implants. Studies have indicated that the HA coated collar promotes osteointegration and bony in growth. This study compares long term aseptic loosening in implants with HA coated collars to those without in the immature skeleton.

Objectives:

To assess the effect of HA coated collars on aseptic loosening in extendable distal femoral replacement prosthesis in the immature skeleton.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 15 - 15
1 Sep 2012
Holleyman R Gikas P Tyler P Coward P Carrington R Skinner J Briggs T Miles J
Full Access

Background

It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome.

Methods

A retrospective study of patients undergoing primary THR at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant musculoskeletal radiologist in both coronal and sagittal planes using post-operative anterior-posterior and lateral pelvic radiographs. Each THR was grouped into valgus, minor-valgus, neutral, minor-varus or varus coronal plane alignment and posterior, minor-posterior, neutral, minor-anterior or anterior sagittal plane alignment. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires after a minimum follow-up of 11 months. Maximum range of passive hip flexion, abduction, adduction, external and internal rotation were measured in clinic. A factorial linear regression model was used to analyse data.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 110 - 110
1 Sep 2012
Al-Hadithy N Gikas P Perera J Aston W Pollock R Skinner J Lotzof K Cannon S Briggs T
Full Access

The surgical treatment of bone tumours can result in large perioperative blood loss due to their large sizes and hypervascularity. Preoperative embolisation has been successfully used to downgrade vascularity, thus reducing perioperative blood loss and its associated complications. Prior to embolization era, blood loss as high as 18,500mL have been reported peri-opratively.

Twenty-six patients with a variety of bone tumours (average size 10.5×7.5×5.5cm), who underwent pre-operative embolisation between 2005 and 2009, were retrospectively studied. The group comprised of 17 females and 9 males. Their mean age was 38 years old. All patients underwent surgical resection within 48 hours of embolization. Mean blood loss was 796mL and required on average 1.1units of blood. We experienced no complications.

Pre-operative arterial embolisation of large, richly vascular bone tumours in anatomically difficult positions, is a safe and effective method of downstaging vascularity and reducing blood loss.