header advert
Bone & Joint Open Logo

Receive monthly Table of Contents alerts from Bone & Joint Open

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Bone & Joint Open at:

Loading...

Loading...

Open Access

Hip

Leg length discrepancy assessment in total hip arthroplasty: is a pelvic radiograph sufficient?



Download PDF

Abstract

Aims

Leg length discrepancy (LLD) is a common pre- and postoperative issue in total hip arthroplasty (THA) patients. The conventional technique for measuring LLD has historically been on a non-weightbearing anteroposterior pelvic radiograph; however, this does not capture many potential sources of LLD. The aim of this study was to determine if long-limb EOS radiology can provide a more reproducible and holistic measurement of LLD.

Methods

In all, 93 patients who underwent a THA received a standardized preoperative EOS scan, anteroposterior (AP) radiograph, and clinical LLD assessment. Overall, 13 measurements were taken along both anatomical and functional axes and measured twice by an orthopaedic fellow and surgical planning engineer to calculate intraoperator reproducibility and correlations between measurements.

Results

Strong correlations were observed for all EOS measurements (rs > 0.9). The strongest correlation with AP radiograph (inter-teardrop line) was observed for functional-ASIS-to-floor (functional) (rs = 0.57), much weaker than the correlations between EOS measurements. ASIS-to-ankle measurements exhibited a high correlation to other linear measurements and the highest ICC (rs = 0.97). Using anterior superior iliac spine (ASIS)-to-ankle, 33% of patients had an absolute LLD of greater than 10 mm, which was statistically different from the inter-teardrop LLD measurement (p < 0.005).

Discussion

We found that the conventional measurement of LLD on AP pelvic radiograph does not correlate well with long leg measurements and may not provide a true appreciation of LLD. ASIS-to-ankle demonstrated improved detection of potential LLD than other EOS and radiograph measurements. Full length, functional imaging methods may become the new gold standard to measure LLD.

Cite this article: Bone Jt Open 2022;3(12):960–968.

Take home message

The conventional method of measuring leg length discrepancy (LLD) on an anteroposterior pelvic radiograph does not correlate well with long leg measurements, and may not provide a true appreciation of LLD. As such, there may be a need to reassess the ongoing use of this measurement of LLD.

Introduction

Leg length discrepancy (LLD) is a common pre- and postoperative issue in total hip arthroplasty (THA) patients. Significant postoperative LLD occurs in up to 32% of patients after THA,1 with consequences including dislocation,2,3 abnormal gait,4 sciatica and back pain,5-7 patient dissatisfaction,8 and litigation.9 As acknowledged by Hofman et al,9 the main causes of LLD after THA are insufficient preoperative planning and errors in surgical execution. Despite a wealth of literature on the subject, several key questions remain over which variables to measure and how to best measure them.

Broadly, LLD can be measured clinically or radiographically.10 Clinical measurements include block measurements and tape measurements between anatomical surface landmarks, whereas radiological measurements include plain radiography and CT.10 Studies have compared these two methods and found radiological measurements to be no more accurate than clinical measurements.11-15

To further complicate matters, there are also two etiologies of LLD: a ‘true’ LLD (tLLD) and an ‘apparent’ LLD (aLLD).16 A tLLD is caused by differences in the actual lengths of bony and soft-tissue anatomy, whereas an aLLD is caused by hip/knee contractures or altered mechanics of the spine, leading the patient to perceive a difference in leg lengths while their bony and soft tissue anatomy may be equal lengths.17 Nakanowatari et al16 found that an aLLD is perceived by almost four times as many patients as tLLD. Similarly, in a sample of 1,114 patients, Wylde et al18 demonstrated that 30% reported aLLD, but only 36% of these patients had a tLLD. Additionally, 17% of patients who did not perceive any LLD in fact had a tLLD.

To have a complete understanding of pre- and postoperative LLD, Sabharwal and Kumar10 proposed that the ideal measurement for assessing LLD should have three qualities. First, accuracy; the measurement targets what is perceived by the patient (aLLD). Second, precision; the measurement has high repeatability and reproducibility. And third, affordability and availability. However, we propose a fourth quality is needed; granularity, in that the measurement can isolate the specific sources of LLD to understand the limitations of correction from surgery.

A conventional radiological technique for measuring LLD when planning a THA has been to draw a line through the inferior aspect of the teardrops on a weightbearing (WB) anteroposterior (AP) pelvic radiograph and measure the vertical distance of the most prominent point on each lesser trochanter (LT) to this inter-teardrop line19-23 (inter-teardrop to LT). This measurement normalizes pelvic obliquity in favour of determining anatomical differences that exist at the ipsilateral and contralateral hips, such as acetabular cartilage degeneration and femoral head wear. Despite limitations, such as internal femoral rotation resulting in difficulty landmarking the lesser trochanter (LT) and magnification error,24 this method is popular. However, it fails to capture other sources of LLD beyond the pelvis and proximal femur, including scoliosis, flexion contractures at the hip or knee, adduction contractures, anatomical variation in femoral and tibial lengths, and ankle deformities.10 An illustration of these sources of LLD can be seen in Figure 1. Hip and knee flexion contractures may cause apparent shortening of the limb, while abduction contractures or equinus deformity of the ankle may lead to an apparent lengthening of the affected hip.10 These factors are likely to influence a patient’s perception of their LLD and an accurate assessment should include consideration of all of them. In fact, Piyakunmala and Sangkomkamhang25 found poor agreement between radiological methods and patient perception. Therefore, it may be said that the pelvic AP radiograph has low accuracy,25 moderate granularity, and high precision.21

Fig. 1 
          Example long-limb EOS imaging to highlight the many different potential sources of leg length discrepancy.

Fig. 1

Example long-limb EOS imaging to highlight the many different potential sources of leg length discrepancy.

To better capture all the possible sources of LLD, other methods of measuring LLD include long-limb imaging, such as CT scanograms,10 and more recently long leg EOS scans (EOS Imaging, France). CT scanograms are taken while the patient is supine and can only be used to determine sources of tLLD, not aLLD. EOS produce simultaneous biplanar images of the subject with very low dose radiation,26 no magnification error,24 and allow 3D reconstruction.26 This shows the full-leg functional stance of the patient in the coronal and sagittal planes and captures all potential sources of LLD (both tLLD and aLLD).

As far as the authors are aware, the only previous study to compare LLD measurements from a pelvic radiograph, such as the inter-teardrop to LT measurement, to long-limb measurements was an investigation by Tipton et al.15 In this study, the authors concluded that LLD measurements on pelvic radiographs were significantly different to a long-limb measurement, and they did not support the use of pelvic radiographs for estimating true LLD. However, this study only investigated one measurement on the long-limb radiography, did not use EOS imaging, which has advantages over plain radiography,24,26 and captured the pelvic radiograph measurements by simply zooming in on the long-limb radiograph, which may limit the applicability of its results due to magnification error.

Therefore, the aims of this study were two-fold. First, to assess the relationship between LLD measurements captured on EOS with the inter-teardrop measurement captured from a WB AP radiograph to determine if the WB AP measurement is reflective of the long-limb LLD. Second, to assess the repeatability and reproducibility of all measurements to understand which long-limb measurement may present as the most precise if this imaging modality was adopted. Our hypothesis was that long-leg EOS measurements would correlate well with each other, but not with the inter-teardrop measurement on WB AP radiograph.

Methods

In all, 93 consecutive patients (100 hips) underwent THA surgery from two experienced surgeons (PJY, CWJ) between July 2020 and August 2021. All patients underwent preoperative surgical planning by 360 Med Care, which included a standardized preoperative EOS scan and WB AP radiograph. Mean age of the patients was 69.6 years (standard deviation (SD) 9.4) and 5o patients (53%) were female. All patients received a Pinnacle (Depuy Synthes, USA) acetabular component and an S-ROM, Corail, or C-Stem (Depuy Synthes) femoral component.

A total of 13 measurements were taken, including the inter-teardrop to LT on WB AP radiograph as a reference standard, pelvic obliquity, femoral and tibial lengths, head centre-to-ankle, head centre-to-floor, anterior superior iliac spine (ASIS)-to-ankle, and ASIS-to-floor. A summary of these measurements can be found in Table I and Table II. Measurements were taken along both anatomical (limb aligned) and functional (gravity aligned) axes and on both the operative and contralateral side. Each measurement was measured twice by an orthopaedic fellow and twice by a qualified surgical planning engineer in RadiAnt DICOM Viewer v2.2.5.10715 (Medixant, Poland), with repeat measurements taken at least two weeks apart to calculate the correlations between measurements and the repeatability of measurements.

Table I.

Summary of landmarks and axes used for our LLD measurements with their corresponding descriptions.

Landmark or axis Type Definition
Functional axis Axis Measured vertically from the superior landmark to a point level with the inferior landmark
Anatomical axis Axis Measured directly from landmark to landmark
Head centre Landmark Defined by drawing a bet-fit circle around the femoral head and taking the centre of the circle
Distal femur Landmark Centre of trochlea groove
Tibial eminence Landmark Junction of eminence (centre of tibial baseplate when a knee arthroplasty is present)
Ankle Landmark Cortical border of distal tibia; tibial plafond
ASIS Landmark Symmetrical landmarks on anterior iliac crest
Floor Landmark The floor; a functional measurement
Adduction Landmark Angle between femoral mechanical axis and the vertical axis
Obliquity Landmark Angle between Bi-ischial line and the horizontal
  1. ASIS, anterior superior iliac spine; LLD, leg length discrepancy.

Table II.

Summary of all measurements taken on either weightbearing anteroposterior radiograph or EOS.

Measurement Imaging modality Axis
Inter-teardrop to LT WB AP radiograph N/A
ASIS-to-ankle EOS Functional
ASIS-to-ankle EOS Anatomical
ASIS-to-floor EOS Functional
Head centre-to-ankle EOS Functional
Head centre-to-ankle EOS Anatomical
Head centre-to-floor EOS Functional
Femur length EOS Functional
Femur length EOS Anatomical
Tibia length EOS Functional
Tibia length EOS Anatomical
Hip adduction EOS (Angular)
Pelvic obliquity EOS (Angular)
  1. EOS scans (EOS Imaging, France).

  1. AP, anteroposterior; ASIS, anterior superior iliac spine; LT, lesser trochanter; N/A, not applicable; WB, weightbearing.

Statistical analysis

Statistical analysis was performed in R Studio v1.3.1903 (R Studio, USA). An α value of 0.05 was used to determine clinical significance. Shapiro-Wilk normality tests confirmed that not all test parameters were normally districted. Therefore, Spearman’s correlations were used to assess the relationship between measurements. Intraclass correlation coefficient (ICC) was used to assess the repeatability of measurements.

Ethics

This retrospective study was approved by the Bellberry Human Research Ethics Committee (study number 201203710).

Results

Spearman’s correlations between all measurements can be found in the correlogram in Figure 2. ASIS and head centre referencing EOS measurements demonstrated the highest correlations with each other (rs > 0.9) and other linear measurements (rs > 0.8). The inter-teardrop measurement had a moderate correlation with ASIS referencing measurements (rs ~ 0.55) and low correlations with other measurements (rs < 0.45). Pelvic obliquity correlated well with ASIS and head centre referencing measurements (rs > 0.8). Femur and tibia lengths had moderate correlations with other, but low correlations with other EOS measurements (0.4< rs<0.6).

Fig. 2 
          Correlogram showing the linear correlation between all measurements.

Fig. 2

Correlogram showing the linear correlation between all measurements.

The most repeatable measurement was head centre-to-floor, followed by ASIS-to-ankle. However, most measurements had an ICC of > 0.9 and all non-angular measurements had an ICC > 0.8. ICC values for all measurements can be seen in Figure 3.

Fig. 3 
          Intra- and interclass correlation coefficients of all measurements.

Fig. 3

Intra- and interclass correlation coefficients of all measurements.

Mean LLD measured on the WB AP radiograph was 1.7 mm (SD 5.6), and 4.2% patients had an absolute LLD of greater than 10 mm. Mean LLD measured using head centre-to-ankle (anatomical axis) was 0.6 (SD 8.0), and 17.9% of patients had an absolute LLD of greater than 10 mm. Mean LLD measured using ASIS-to-ankle (anatomical axis) was 3.1 (SD 12.2) and 32.6% of patients had an absolute LLD of greater than 10 mm. The percentage of patients with greater than 10 mm LLD measured using these long leg measurements was statistically different from the AP inter-teardrop LLD measurement (p < 0.005). A spread of LLDs using different measurements along both anatomical and functional axes can be seen in Figure 4.

Fig. 4 
          Box and whisker plots to demonstrate the variability of leg length discrepancy measurements when using different landmarks and axes.

Fig. 4

Box and whisker plots to demonstrate the variability of leg length discrepancy measurements when using different landmarks and axes.

Discussion

LLD is a critical consideration in THA as large LLDs may lead to adverse outcomes for the patient.2-8 Lack of clarity over the best technique of measuring and addressing LLD has led to this being one of the most widely litigated issues in orthopaedic practice.9 Conventionally, clinicians may assess LLD radiologically on a WB AP pelvic radiograph;19-23 however, this only captures anatomical sources of LLD at the level of the hip joint.19 Other methods of measuring LLD include CT scanograms,15 tape measure,10 and block measurements,10 but these are subject to various limitations regarding their accuracy, precision, and granularity.10,14,20,27 Therefore, using a consecutive series of patients undergoing THA, we sought to investigate whether functional EOS imaging might provide a more complete understanding of LLD by addressing the four qualities that a LLD measurement should have accuracy, precision, affordability and availability, and granularity.

With no correlation coefficient higher than 0.57, we found that the conventional inter-teardrop to LT measurement of LLD does not correlate well with other long-limb measurements. We also found reduced inter- and intraobserver agreement for this measurement, indicating limitations in its repeatability and reproducibility. Therefore, similar to Tipton et al,15 Kjellberg et al,20 and Sabharwal et al,10 our results call into question the validity of using the WB AP radiograph to measure LLD as they indicate that it does not provide a complete understanding of LLD.

The ASIS-to-ankle measurement in both the functional and anatomical axes was observed to have a high repeatability (ICC > 0.9) and strong correlations with pelvic obliquity and other EOS measurements. This measurement may provide greater detection of clinical LLD than other measurements and, where available, there is a strong case for use of this measurement to determine pre- and postoperative LLD. This is enhanced by the fact that EOS imaging has been shown to not be subject to magnification error, regardless of subject BMI, whereas plan radiography is,24 and is also becoming more widely available. However, it should be noted that there is a potential oversensitivity of the ASIS-to-ankle measurement to sources of LLD that naturally correct postoperatively. For example, intraoperative lengthening in response to a hip contracture that corrects after surgery may lead to excessive lengthening. For this reason, the ASIS-to-ankle measurement may have limitations regarding its granularity and the surgeon may need to determine whether to correct these types of postural sources of preoperative LLD or utilize additional methods.

To further explore the notion of the WB AP radiograph not capturing all sources of LLD, example EOS imaging can be found in Figure 5. This imaging is of a 49-year-old female requiring THA on her left hip due to secondary osteoarthritis from developmental dysplasia of the hip. As seen on the left in Figure 5(a), the inter-teardrop line on WB AP radiograph shows a 7.2 mm LLD. Conventional planning here would be to correct this LLD by lengthening the operative hip by 7 to 8 mm intraoperatively to yield equal leg lengths. However, with the use of the long-leg functional alignment from EOS imaging (Figure 5(b), it is apparent that the patient has different femoral and tibial lengths. These sources of LLD manifest as the left leg being 3 to 4 mm longer. Therefore, attempting to restore the leg lengths by using the WB AP radiograph alone could lead to an operative leg that is over a centimetre longer postoperatively, which has been associated with poor patient outcomes.2-8

Fig. 5 
          EOS imaging from a patient 49-year-old female who underwent total hip arthroplasty. On the left is a zoomed-in recreation of a standing anteroposterior radiograph from the EOS. On the right is the full EOS image of the long leg alignment.

Fig. 5

EOS imaging from a patient 49-year-old female who underwent total hip arthroplasty. On the left is a zoomed-in recreation of a standing anteroposterior radiograph from the EOS. On the right is the full EOS image of the long leg alignment.

The results of our study should be interpreted within the context of its limitations. First, although EOS has utility in its ability to capture the long-leg functional stance in simultaneous biplanar images, it requires that the subject stand with one-foot forwards and one-foot backwards to ensure the knee joints are not overlapping. This may create an aLLD where one does not exist due to the functional stance of the subject. Second, this study did not include postoperative data, patient-reported outcome measures (PROMs), or measurements of the patient’s perceived LLD, which would provide insight into the mechanisms of functional correction from pre- to postoperative states and how patients subjectively experience any LLDs that are present. For example, pre- and postoperative data will be required to understand how much a hip contracture corrects postoperatively, and how this subsequently affects any aLLD. Further to this point, although the ASIS-to-ankle measurement has been shown to be precise, our study has not linked this measurement to the patients’ experience of LLD as we did not include clinical measurements. Therefore, we have not yet demonstrated its accuracy. Third, we did not include offset measurements, which also impact the patient’s perception of LLD. Fourth, although EOS imaging machines are becoming more widely available, they are not a standard service at radiology centres. Therefore, the results of this study may not be implementable by all clinicians due to a lack of availability. Future work may investigate maquet view imaging, which is more widely available, to understand if this better fulfills the four qualities required of LLD measurements. Finally, despite EOS presenting an improvement to previously used methods of radiologically measuring LLD, EOS remains somewhat limited in its granularity for determining which sources of LLD should and should not be corrected from surgery.

In conclusion, the inter-teardrop to LT measurement taken on an AP WB pelvic radiograph, which is widely considered the industry standard for measuring LLD, does not correlate well with measurements taken on EOS imaging. Therefore, there may be a need to reassess the ongoing use of this measurement of LLD. As a arthroplasty, long-limb functional imaging methods may provide a more complete understanding of all sources of LLD that exist and could become the new ‘gold standard’ to create postoperatively equal aLLD, which has been proposed as the better target.16 Specifically, we propose that the ASIS-to-ankle (anatomical) measurement, which exhibited a high correlation to other linear measurements and the highest ICC, may be the best measurement of LLD. Further work should involve the collection of pre- and postoperative EOS imaging, with the addition of patient perceptions of LLD, to understand how contractures correct postoperatively, and to build predictive algorithms that can be integrated into preoperative planning.


Correspondence should be sent to Max Hardwick-Morris. E-mail:

References

1. Desai AS , Dramis A , Board TN . Leg length discrepancy after total hip arthroplasty: a review of literature . Curr Rev Musculoskelet Med . 2013 ; 6 ( 4 ): 336 341 . Crossref PubMed Google Scholar

2. Plaass C , Clauss M , Ochsner PE , Ilchmann T . Influence of leg length discrepancy on clinical results after total hip arthroplasty--a prospective clinical trial . Hip Int . 2011 ; 21 ( 4 ): 441 449 . Crossref PubMed Google Scholar

3. Konyves A , Bannister GC . The importance of leg length discrepancy after total hip arthroplasty . J Bone Joint Surg Br . 2005 ; 87-B ( 2 ): 155 157 . Crossref PubMed Google Scholar

4. Abraham WD , Dimon JH . Leg length discrepancy in total hip arthroplasty . Orthop Clin North Am . 1992 ; 23 ( 2 ): 201 209 . Crossref Google Scholar

5. Gurney B , Mermier C , Robergs R , Gibson A , Rivero D . Effects of limb-length discrepancy on gait economy and lower-extremity muscle activity in older adults . J Bone Joint Surg Am . 2001 ; 83-A ( 6 ): 907 915 . Crossref PubMed Google Scholar

6. Turula KB , Friberg O , Lindholm TS , Tallroth K , Vankka E . Leg length inequality after total hip arthroplasty . Clin Orthop Relat Res . 1986 ; 202 ( amp;NA ): 163 . Crossref PubMed Google Scholar

7. Friberg O . Clinical symptoms and biomechanics of lumbar spine and hip joint in leg length inequality . Spine . 1983 ; 8 ( 6 ): 643 651 . Crossref PubMed Google Scholar

8. Giles LG , Taylor JR . Low-back pain associated with leg length inequality . Spine (Phila Pa 1976) . 1981 ; 6 ( 5 ): 510 521 . Crossref PubMed Google Scholar

9. Hofmann AA , Skrzynski MC . Leg-length inequality and nerve palsy in total hip arthroplasty: a lawyer awaits! Orthopedics . 2000 ; 23 ( 9 ): 943 944 . Crossref PubMed Google Scholar

10. Sabharwal S , Kumar A . Methods for assessing leg length discrepancy . Clin Orthop Relat Res . 2008 ; 466 ( 12 ): 2910 2922 . Crossref PubMed Google Scholar

11. Clarke GR . Unequal leg length: an accurate method of detection and some clinical results . Rheumatol Phys Med . 1972 ; 11 ( 8 ): 385 390 . Crossref PubMed Google Scholar

12. Cleveland RH , Kushner DC , Ogden MC , Herman TE , Kermond W , Correia JA . Determination of leg length discrepancy. A comparison of weight-bearing and supine imaging . Invest Radiol . 1988 ; 23 ( 4 ): 301 304 . Crossref PubMed Google Scholar

13. Terry MA , Winell JJ , Green DW , et al. Measurement variance in limb length discrepancy: clinical and radiographic assessment of interobserver and intraobserver variability . J Pediatr Orthop . 2005 ; 25 ( 2 ): 197 201 . Crossref PubMed Google Scholar

14. Lampe HI , Swierstra BA , Diepstraten AF . Measurement of limb length inequality: comparison of clinical methods with orthoradiography in 190 children . Acta Orthop Scand . 1996 ; 67 ( 3 ): 242 244 . Crossref Google Scholar

15. Tipton SC , Sutherland JK , Schwarzkopf R . The Assessment of Limb Length Discrepancy Before Total Hip Arthroplasty . J Arthroplasty . 2016 ; 31 ( 4 ): 888 892 . Crossref PubMed Google Scholar

16. Nakanowatari T , Suzukamo Y , Suga T , Okii A , Fujii G , Izumi S-I . True or apparent leg length discrepancy: which is a better predictor of short-term functional outcomes after total hip arthroplasty? J Geriatr Phys Ther . 2013 ; 36 ( 4 ): 169 174 . Crossref Google Scholar

17. Blake RL , Ferguson H . Limb length discrepancies . J Am Podiatr Med Assoc . 1992 ; 82 ( 1 ): 33 38 . Crossref PubMed Google Scholar

18. Wylde V , Whitehouse SL , Taylor AH , Pattison GT , Bannister GC , Blom AW . Prevalence and functional impact of patient-perceived leg length discrepancy after hip replacement . Int Orthop . 2009 ; 33 ( 4 ): 905 909 . Crossref PubMed Google Scholar

19. Meermans G , Malik A , Witt J , Haddad F . Preoperative radiographic assessment of limb-length discrepancy in total hip arthroplasty . Clin Orthop Relat Res . 2011 ; 469 ( 6 ): 1677 1682 . Crossref PubMed Google Scholar

20. Kjellberg M , Al-Amiry B , Englund E , Sjödén GO , Sayed-Noor AS . Measurement of leg length discrepancy after total hip arthroplasty. The reliability of a plain radiographic method compared to CT-scanogram . Skeletal Radiol . 2012 ; 41 ( 2 ): 187 191 . Crossref PubMed Google Scholar

21. McWilliams AB , Grainger AJ , O’Connor PJ , Redmond AC , Stewart TD , Stone MH . Assessing reproducibility for radiographic measurement of leg length inequality after total hip replacement . HIP Int . 2012 ; 22 ( 5 ): 539 544 . Crossref PubMed Google Scholar

22. Ranawat CS , Rao RR , Rodriguez JA , Bhende HS . Correction of limb-length inequality during total hip arthroplasty . J Arthroplasty . 2001 ; 16 ( 6 ): 715 720 . Crossref PubMed Google Scholar

23. Keršič M , Dolinar D , Antolič V , Mavčič B . The impact of leg length discrepancy on clinical outcome of total hip arthroplasty: comparison of four measurement methods . J Arthroplasty . 2014 ; 29 ( 1 ): 137 141 . Crossref PubMed Google Scholar

24. Chiron P , Demoulin L , Wytrykowski K , Cavaignac E , Reina N , Murgier J . Radiation dose and magnification in pelvic X-ray: EOS imaging system versus plain radiographs . Orthop Traumatol Surg Res . 2017 ; 103 ( 8 ): 1155 1159 . Crossref Google Scholar

25. Piyakunmala K , Sangkomkamhang T . Measurement of patient’s perception on limb-length discrepancy compared with weight-bearing orthoroentgenography in total hip arthroplasty: a prospective study . J Arthroplasty . 2018 ; 33 ( 7 ): 2301 2305 . Crossref Google Scholar

26. Park K-R , Lee J-H , Kim D-S , et al. The comparison of lower extremity length and angle between computed radiography-based teleoroentgenogram and EOS Imaging system . Diagnostics (Basel) . 2022 ; 12 ( 5 ): 1052 . Crossref Google Scholar

27. Jonson SR , Gross MT . Intraexaminer reliability, interexaminer reliability, and mean values for nine lower extremity skeletal measures in healthy naval midshipmen . J Orthop Sports Phys Ther . 1997 ; 25 ( 4 ): 253 263 . Crossref PubMed Google Scholar

Author contributions

M. Hardwick-Morris: Validation, Formal analysis, Investigation, Visualization, Project administration, Writing – original draft.

E. Wigmore: Validation, Investigation, Writing – review & editing.

J. Twiggs: Conceptualization, Metholodolgy, Formal analysis, Investigation, Visualization, Writing – review & editing.

B. Miles: Conceptualization, Resources, Supervision, Writing – review & editing.

C. W. Jones: Conceptualization, Metholodolgy, Data curation, Supervision, Writing – review & editing.

P. J. Yates: Conceptualization, Metholodolgy, Data curation, Supervision, Writing – review & editing.

Funding statement

The author(s) received no financial or material support for the research, authorship, and/or publication of this article.

ICMJE COI statement

M. Hardwick-Morris is an employee of 360 Med Care and Enovis, who supported this research. C. W Jones declares being a consultant to 360 Med Care, which is related; grants from DePuy Synthes and Zimmer Biomet; consulting fees from DePuy Synthes and NavBit; payment for lectures or presentations, and support for attending meetings from Medacta and DePuy Synthes; stock options for NavBit; and being co-director of Orthopaedic Research Foundation of Western Australia, all of which are unrelated to this article. B. Miles declares consulting fees and stock/stock options from 360 Med Care, which are related; stock/stock options, royalties, and an employee of Enovis, which are related; consultant to Johnson & Johnson; grants or contracts from NSW Health Medical Device Fund, Australian Tax Office, AusIndustry, and Johnson & Johnson; royalties from Corin; consulting fees from Johnson & Johnson, all of which are unrelated. J. Twiggs and E. Wigmore declare being employees of 360 Med Care and Enovis, which are related. P. J. Yates declares being a consultant to 360 Med Care, which is related; consulting fees from Matortho, DePuy, and Cardinal; and payment or honoraria for lectures or presentations from DePuy, which are unrelated to this article.

Acknowledgements

The authors would like to acknowledge 360 Med Care and Enovis for their support of this research.

Ethical review statement

Bellberry Human Research Ethics Committee (study number 201203710).

Open access funding

The authors report that they received open access funding for this manuscript from 360 Med Care and Enovis.

© 2022 Author(s) et al. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credited. See https://creativecommons.org/licenses/by-nc-nd/4.0/